An Chéad 1234567 Last

 

Scannán feadánacha chomhdhúile sileacain

 

Níl. Cineál Toise Uimhir Poill Fad
(mm)
Limistéar scagacháin
(m2)
Beachtas scagtha(nm) Pictiúr
1
 
JMtech-SICT-25-3-19-1178
 
productcate-145-92 19
 
1178
 
0.21
 
40/100/500
 
productcate-147-126
2
 
JMtech-SICT-30-4-19-1016
 
productcate-173-115 19
 
1016
 
0.24
 
40/100/500
 
productcate-147-126
3
 
JMtech-SICT-31-4.2-19-1100-H
 
productcate-677-450 19
 
1100 0.31
 
40/100/500
 
productcate-150-137
4
 
JMtech-SICT-32-3.8-19-1100
 
productcate-172-97 19
 
1100
 
0.25
 
40/100/500
 
productcate-147-126
5
 
JMtech-SICT-32-3.8-19-1200
 
productcate-172-97 19
 
1200
 
0.27
 
40/100/500
 
productcate-147-126
6
 
JMtech-SICT-40-4-37-1200
 
productcate-153-112 37
 
1200
 
0.56
 
20/40/100/500
 
productcate-151-132
7
 
JMtech-SICT-40-5.6-19-1828.8-H
 
productcate-158-103 19
 
1828.8 0.71
 
20/40/100/500
 
productcate-159-137
8
 
JMtech-SICT-40-5.6-19-1500-H
 
productcate-158-103 19
 
1500 0.58
 
20/40/100/500 productcate-159-137
9
 
JMtech-SICT-40-4-37-1500-H
 
productcate-679-468 37
 
1500 0.81
 
20/40/100/500
 
productcate-156-140
10
 
JMtech-SICT-46-4-61-1230
 
productcate-697-514 61
 
1230
 
0.92
 
20/40/100/500
 
productcate-161-142
11
 
JMtech-SICT-46-X-81-1230-F
 
productcate-492-464 81
 
1230
 
1.27
 
20/40/100/500 productcate-154-137
12
 
JMtech-SICT-46-2.7-127-1230 productcate-130-87 127 1230
 
1.32 20/40/100/500
 
productcate-151-132
13
 
JMtech-SICT-50-4.9-37-1500-H
 
productcate-173-114 37
 
1500
 
1
 
40/100/500
 
productcate-156-140
14
 
JMtech-SICT-50-3.76-61-1500-H
 
productcate-158-139 61
 
1500
 
1.21
 
40/100/500
 
productcate-139-138
15
 
JMtech-SICT-146-4.3-524-1100
 
membrane 524
 
1100
 
7.8
 
40/100/500
 
productcate-163-145
16
 
JMtech-SICT-190-3.2-1701-1500
 
tubular membrane 1701
 
1500
 
25
 
40/100/500
 
productcate-148-132
17
 
JMtech-SICT-166-3-1086-880
 
productcate-831-634 1086
 
880
 
9.8
 
40/100/500
 
productcate-126-145

 

Nótaí:Sampla"JMtech-SICT-25-3-19-1178"
Jmtech: Giorrúchán cuideachta Jianmo
SICT:Scannán feadánacha SIC
25: Is é 25mm trastomhas
3: trastomhas cainéal 3mm
19: cainníocht cainéal 19个
1178: fad 1178mm
JMtech-SICT-40-5.6-19-1828.8-H Ag ionadú do Heicseagán
JMtech-SICT-46-X-81-1230-F Léiríonn 'F' cruth earnála

Mar cheann de na monaróirí agus na soláthróirí membrane feadánacha tosaigh sa tSín, cuirimid fáilte mhór roimh duit membrane feadánacha saincheaptha mórdhíola ónár mhonarcha. Le haghaidh níos mó táirgí saor, déan teagmháil linn anois.