245. C: Déileálann ár monarcha le fuíolluisce alcóil. Seo a leanas na príomhchoinníollacha: trosc<40000 mg/L pH 5-6SS 20000 mg/L TN 500 mg/L SO42- 35 mg/L Temperature 65-75℃. The proposed process is to set up a solid-liquid separator at the front end of the treatment system and connect it to a USAB+ three-tank oxidation ditch at the back. Is this process suitable? If the UASB process is used, should high temperature or medium temperature be used? What else should be paid attention to in the design? A: (1) Medium temperature is better for anaerobic reaction. If the temperature is too high, it should be cooled down. (2) Since anaerobic reaction is sensitive to water quality, water volume and shock load, a large-capacity regulating tank should be built. This is the basic guarantee for the stable operation of anaerobic reaction. (3) Pretreatment process, coarse and fine screens or grit chambers, nutrient salt and pH control systems should be set up according to the characteristics of water quality. (4) It is better to use EGSB or IC for the anaerobic part, and it is recommended to use Carrousel oxidation ditch for the aerobic part.
246. Ceist: Is é scála cóireála ár ngléasra ná 30,000 m3/d. Glacaimid leis an bpróiseas cóireála ocsaídiúcháin hidrealú + teagmhála bitheolaíoch. Tar éis dhá bhliain a oibriú, bíonn sloda snámh i gcónaí ag an umar dríodair tánaisteach (ualach thart ar 0.9). Rinneamar iarracht modhanna coigeartaithe éagsúla a thriail ach gan aon leas a bhaint as. Creidimid ar dtús go bhfuil ualach dearaidh an umair dríodair thánaistigh ró -ard. Deimhnigh le do thoil. Freagra: Cé nach bhfuil a fhios againn an bhfuil an fheidhmíocht socraithe sloda go maith, ó ualach dromchla an dearadh umar dríodair tánaisteach, tá do thuairim ceart. Tá míthuiscint ann anois nach bhfuil an -chuid bithfhilm ag an umar ocsaídiúcháin teagmhála, agus is féidir le hualach dromchla an umair dríodair a bheith níos airde. Tá an t -ualach dromchla atá ag go leor umar dríodair tar éis an umar ocsaídiúcháin teagmhála cosúil leis an umar dríodair sloda gníomhachtaithe. Tá sé seo mícheart. Ba chóir go mbeadh ualach dromchla an umair dríodair membrane níos lú ná an t -umar dríodair láibe, toisc go mbíonn feidhmíocht socraithe an bhithbhreoslaí seid lag de ghnáth.
247. Ceist: An mhaidin seo, fuaireamar amach gur thit na ceithre mhéadar ocsaigine tuaslagtha in umar aeraithe ár stáisiúin séarachais go tobann ó 4.0mg/L go beagnach 0, agus méadaíodh toirt aeraithe an umair bithcheimiceach. Ach níor tháinig méadú ar an luach DO fós. Ós rud é go bhfuil luachanna taispeána na gceithre mhéadar ocsaigine tuaslagtha mar an gcéanna, is féidir an teip mhéadair ocsaigine tuaslagtha a chur as an áireamh. FREAGRA: Ba chóir a dheimhniú an bhfuil a lán trosc neamhorgánach ag dul isteach sa fuíolluisce.
248. Ceist: Cén chaoi a ndéileáiltear go ginearálta le hiain luaidhe i bhfuíolluisce leictreaphlátála? Tá riachtanais ag scaoileadh fuíolluisce maidir le suilfíd, ach an bhfuil aon riachtanais ann maidir le sulfáit? Freagra: Tá go leor bealaí ann chun ian luaidhe a bhaint i bhfuíolluisce leictreaphlátála, mar shampla leictrealú, asaithe ag asaitheoirí amhail carbón gníomhachtaithe, srl. Níl aon teorainn ar thiúchan sulfáit sa chaighdeán scaoilte fuíolluisce.
249. Ceist: Tá toirt uisce de 300 méadar ciúbach/lá, cóireáil anaeróbach ar feadh 1.5 lá ag gléas cóireála séarachais ospidéil, agus déan teagmháil le ocsaídiú ar feadh 1.5 lá. Is fuíolluisce othar seachtrach agus d'othair chónaitheacha den chuid is mó é an tionchar. Tá an tionchar buí éadrom agus tá an éifeacht anaeróbach an -lag. Is é an COD eisiltigh thart ar 300mg/L agus is é 55mg/L nítrigin amóinia. Is é an COD eisilteach ocsaídiúcháin teagmhála ná 180mg/L agus is é 35mg/L nítrigin amóinia. Bhí mé ag saothrú ar feadh beagnach leathbhliain, ach is é an éifeacht seo amháin. Tá sloda curtha agam go minic ach tá sé gan úsáid. Thosaigh mé ag cur plúir leis le déanaí, agus tá feabhas beag tagtha air. Mar gheall ar shrianta costais, ní chuirim ach 10 kg de phlúr gach lá leis. Conas is féidir liom bithfhilm a chothú go héifeachtach? Freagra: Ba chóir duit a dheimhniú an gcomhlíontar na coinníollacha bunúsacha rialaithe, mar shampla: an éifeacht corraitheach, an teocht, an cóimheas cothaitheach (cibé an bhfuil fosfar ann) den umar anaeróbach agus an alcaileacht agus an ocsaigin tuaslagtha den umar ocsaídiúcháin teagmhála. Toisc go bhfuil an réamhrá ró -shimplí, ní féidir liom ach freagra mar seo a fhreagairt.
250 Ceist: Glacann an gléas cóireála fuíolluisce inár n -aonad modh A/O. De ghnáth, is é 38mg/L an nítrigin amóinia sa linn A agus is é 9mg/L an linn O. Anois tá an nítrigin amóinia sa linn A 60mg/L agus is é 45mg/L an linn snámha O. N'fheadar an mbaineann an teip an nítrigin amóinia a laghdú leis an méadú ar shuilfíd? Lá de suanbhruith a bhí ann, ach níor tháinig feabhas ar an scéal. Níor athraigh na coinníollacha oibriúcháin. Go tobann, bhí sé mar seo. Níor tharla ach dhá rud i lár: 1. Mhéadaigh suilfíd; 2. Mhéadaigh COD, agus bhí ola agus uisce ann. Ina dhiaidh sin, bhí sé níos ísle, agus d'iompaigh an sloda ó donn go dubh. Cad ba cheart dom a dhéanamh anois? Freagra: Níl a fhios agam cé chomh hard is atá an tiúchan sulfide, ach ón staid a chuir tú ar fáil, níl an fhéidearthacht nimhiú sloda ard. Is é an chúis is mó atá leis ná go gcuireann soláthar neamhleor ocsaigine anaeróbachas sloda. Ní bhaineann go leor ocsaigine leis na cásanna roimhe seo. Ba chóir an méid ocsaiginithe a mhéadú oiread agus is féidir agus ba chóir an iontógáil uisce a laghdú. Mura féidir an méid ocsaiginithe a mhéadú, is féidir an méid urscaoilte sloda a mhéadú go cuí chun an tiúchan sloda a laghdú. Dealraíonn sé go bhfuil an cur chuige seo contrártha leis na trí - Prionsabal Cothromaíochta Céim toisc go bhfuil an t -ualach sloda níos airde, ach níl sé amhlaidh. Toisc gur féidir le méadú cuí a dhéanamh ar an méid urscaoilte sloda níos mó substaintí a scaoiltear sa sloda, tá sé úsáideach freisin an easpa ocsaigine a mhaolú. Beidh an chóireáil seo níos fearr.
251. C: Tá COD ár bhfuíolluisce idir 500 agus 600 mg/L. D'úsáideamar modh téachta + PAM + modh snámhachta, ach ní raibh an éifeacht cóireála go maith. D'úsáid mé sárocsaíd hidrigine + sulfáit neamhfheiriúil le haghaidh cóireála turgnamhaí agus bhí an éifeacht go maith (bhí COD thart ar 150 mg/L). Anois tá ceist ann: an féidir an deascán hiodrocsaíde iarainn a bhaint trí shnámhphointe brú? A: Tá domhantarraingt shonrach deascán hiodrocsaíde iarainn sách mór, mar sin níl sé oiriúnach le haghaidh snámhachta.
252. C: Maidir leis an bpróiseas teagmhála ocsaídiúcháin Biofilm Foirmiú: 1. Ag tús an umar O, cuireadh 5% de thoirt an umair de sloda dí -uiscithe leis. Cé nach raibh sloda i bhfad níos gníomhaí ann, cén chaoi ar imigh an sloda marbh as an gcóras? An raibh sé díláraithe in orgánaigh aonair agus an raibh sé ag sileadh amach leis an uisce nó leis an díleá aeróbach? Nó an raibh sé in éineacht leis an sloda marbh {- tar éis insreabhadh uisce leanúnach agus sileadh amach as an umar dríodair mar flocs beag? 2. Tar éis aeraithe go dtí go gcloítear le méid beag sloda leis an bhfillteoir, má laghdaítear an tiúchan sloda ar fionraí san uisce chun fás tapa an sloda ar an bhfiller a éascú trí chothaithigh a úsáid go hiomlán? Ag an am seo, cad é an tiúchan cuí de sloda ar fionraí san uisce? 3. Cad iad na modhanna a chabhródh le greamaitheacht sloda leis an filler agus le hatáirgeadh tapa agus le fás sloda ar an bhfillteoir? Freagra: 1. Tá roinnt baictéar aeróbach díomhaoin sa SO {- ar a dtugtar sloda marbh, a aisghabhfaidh a ngníomhaíocht faoi choinníollacha aeróbacha. Is féidir le baictéir roinnt solad so -ghalaithe a dhíghrádú freisin. Beidh roinnt sloda ag snámh amach le huisce tar éis díláraithe, agus scaoilfear cuid acu trí sloda iarmharach {. 2. tar éis méid beag sloda a chloíonn leis an líontóir a nochtadh don atmaisféar, ba cheart an iontógáil uisce a mhéadú (ba chóir na cothaithigh a fhorlíonadh in am). Ag an am seo, is fearr gan sloda a bheith agat san uisce {. 3. chun an t -am dífhabhtaithe a ghiorrú, ní féidir sloda díhiodráitithe a úsáid. Ba chóir sloda tiubhaithe a úsáid roimh dhíhiodráitiú le haghaidh ionaclaithe, nó ba chóir sloda síl a spraeáil ar an bhfiller sula gcuirtear uisce leis an linn snámha bithcheimiceach. Ar ndóigh, tá riachtanais theicniúla sa phróiseas saothraithe ar leith.
253. Q: Táimid ag dífhabhtú ionad cóireála fuíolluisce leathair, an próiseas: scáileán {- umar rialaithe - dhá - umar imoibriúcháin flocculation céim - Sediment umar {{{{{} {}} {}} {}} umar sloda emediation}}} umar sloda}}} umar sloda}}} umar 7} umar 7} umar 7} umar slogge a chur i bhfeidhm} umar umar} umar umar sloda} umar umar sloda umar umar umar umar {}}}}}} a bheith ann Umar ocsaídiúcháin - umar dríodair tánaisteach. Is é an méid fuíolluisce ná 700m3/d, tá an trosc tionchair níos mó ná 3000 mg/L, agus ceanglaítear ar an COD eisiltigh a bheith faoi bhun 90 mg/L. Is é an t -umar sloda gníomhachtaithe SRT ná 9.3 uair an chloig, is é an t -umar ocsaídiúcháin teagmhála SRT 4 uair an chloig, agus is é an t -umar dríodair idirmheánach agus an t -umar dríodair tánaisteach SRT 2 uair an chloig. Tar éis an chéad breisiú sloda, ní raibh aon aerú ann, agus rinneadh cultúr aife leanúnach. Bhí an cúr agus an boladh an -trom, agus níorbh fhéidir an ráta bainte den linn bhithcheimiceach a fheabhsú. Níos déanaí, cuireadh an dara sloda leis, agus bhí an éifeacht soiléir tar éis cúpla lá den aerú agus de réir a chéile ag méadú an méid uisce cóireáilte. Ba é COD eisilteach an phróisis fhisiciúil agus cheimiceach ná thart ar 700-1000 mg/L, agus bhí COD an umair dríodair idirmheánach níos mó ná 200 mg/L. Tar éis ocsaídiúcháin teagmhála, bhí an COD fós níos mó ná 100 mg/L, a bhí níos airde fós ná an ceanglas dearaidh (faoi bhun 90mg/L). Le linn na hoibríochta, bhí filleadh sloda ag an umar sloda gníomhachtaithe agus an t -umar ocsaídiúcháin teagmhála. Níos déanaí, rinneadh an t -umar sloda gníomhachtaithe a choigeartú chun filleadh, agus níor cuireadh an t -umar ocsaídiúcháin teagmhála ar ais. Mar sin féin, mhéadaigh an cúr san umar ocsaídiúcháin teagmhála. Draenáladh an t -umar dríodair tánaisteach ar feadh cúpla nóiméad gach dhá uair an chloig, ach bhí a lán SS fós san eisilteach, agus níor feabhsaíodh an éifeacht bainte. Anois tá cúpla ceist agam le cur: 1. Cathain a bhíonn sé oiriúnach sloda a dhraenáil tar éis sloda a chur leis? Cad é an caighdeán (gan aon choinníollacha chun SVI agus MLSS a thomhas)? 2. Is é an fosfar iomlán san eisilteach fisiciceimiceach ach cúpla deichiú, agus tá an C/P an -íseal. Tá an sloda san umar sloda gníomhachtaithe ag leathnú anois. N'fheadar an mbaineann sé leis seo? 3. Más mian leat méid an leasacháin fosfáite a ríomh, conas é a ríomh? An féidir leat sampla a thabhairt (comhpháirt éifeachtach de leasachán fosfáite: P2O 5=12%)? 4. Tar éis an t -umar ocsaídiúcháin teagmhála a chur ar ais, is léir go bhfuil an cúr ar dhromchla na linne níos mó ná nuair a chuirtear ar ais é. An bhfuil sé éasca do LAS dromchla na linne a chlúdach tar éis é a chasadh nuair a bhíonn níos lú sloda ar fionraí sa linn? An bhfuil an tuairisceán nó nach gcinnfidh sé de réir a ualaigh? An bhfuil sé indéanta roinnt sloda ar fionraí a chur leis an ualach a roinnt nuair a bhíonn an MLSS ard agus an sloda ar fionraí a laghdú nuair a bhíonn an MLSS íseal agus gan ach brath ar an scannán chun an t -uisce a chóireáil? 5. An méadóidh an leathnú sloda luach pH an tionchair, agus an gcoinneoidh sé luach pH an umar aeraithe idir 8-9 ar feadh 3-5 lá sula gcuireann sé cothaithigh leis an athnuachan? 6. Nuair a bhíonn an SV chomh hard le 35-60 le linn leathnú, ar chóir an t-urscaoileadh sloda a mhéadú chun an sloda a bhaint le drochfheidhmíocht socraithe? Freagra: Is iad seo a leanas na freagraí: 1. Mura féidir MLSS a thomhas, ní mór SV a thomhas, ar féidir leis méid na feidhmíochta sloda agus sloda a chinneadh go garbh. Anois ní dhéantar an sloda a ionaclú agus a shaothrú ach sloda, agus níl aon ghá le breithniú a dhéanamh ar urscaoileadh sloda . 2. is féidir le fosfar neamhleor a bheith ina chúis le droch -fheidhmíocht sloda agus tionchar a imirt ar fhás sloda. Ba chóir fosfar a rialú ag thart ar 1% den BOD5 den tionchair bhithcheimiceach. Mura bhfuil sé neamhleor, ba chóir é a chur leis, agus is gá a dheimhniú freisin an gcomhlíonann N na riachtanais . 3. Mura ndéantar BOD5 a thomhas, ní féidir an méid fosfair a chuirtear leis a chinneadh ach trí thriail agus earráid. Cuirtear an tiúchan fosfair in iúl mar fhosfar eiliminteach. Má chuirtear x kg de fhosfar íon leis in aghaidh na huaire, an méid 12% P2O5 le cur leis {= x × P2O5/P × 12% . 4. Is gnáth go bhfuil an cúr ar dhromchla an locháin ocsaídiúcháin teagmhála níos mó ná an méid sin nuair a dhéantar é a léiriú tar éis an ocsaídiúcháin teagmhála nach bhfuil an pond. Anois is cóireáil shármhaith é an sloda athfhillteach a úsáid chun an cúr a laghdú, ní réiteach bunúsach. Go hiondúil, laghdóidh an cúr tar éis don bhithfhilm a bheith déanta go hiomlán. Más rud é nach féidir leis a bheith imithe i léig, is féidir é a spraeáil le huisce chun deireadh a chur leis an cúr . 5. Ní féidir a mheas go bhfuil do sloda reatha leathnú. D'fhéadfadh sé a bheith ina fhadhb fós de chóimheas cothaitheach. Is féidir pH an uisce ionraoin locháin bhithcheimiceach a rialú ag 6 ~ 9. Ina theannta sin, ba chóir a thabhairt faoi deara nach ndéanfar an sloda a athfhógairt le linn gnáthoibriú an mhodha ocsaídiúcháin teagmhála. Is féidir é a athfhógairt go cuí le linn na tréimhse cultúir, ach ní féidir é a athfhriotal nuair nach leor an cothú. Mura bhfuil an cóimheas cothaitheach sásta, tá sé gan úsáid sloda a chur leis.
254. C: Tar éis an t -umar dríodair tánaisteach den phróiseas ocsaídiúcháin teagmhála a úsáid, má sheoltar an sloda san umar dríodair tánaisteach ar ais chuig an umar ocsaídiúcháin teagmhála, nó ar chóir an sloda a urscaoileadh ag an gcéim níos déanaí de shaothrú sloda? Má fhaightear líon mór de phéisteanna clog agus de phéisteanna brainseach sa scrúdú micreascópach sloda agus má tá siad gníomhach, an féidir a mheas go n -éiríonn leis an mbithfilm ocsaídiúcháin teagmhála agus nach bhfuil aon ghá é a thabhairt ar ais (i dtéarmaí simplí, conas an tuairisceán a rialú, má stoptar é ach amháin nuair a bhíonn an t -uisce luchtaithe go hiomlán)? A: Má tá méid beag bithbhreoslaí ar an bhfillteoir, ní gá an sloda san umar dríodair tánaisteach a chur ar ais, ar shlí eile beidh na miocrorgánaigh sa sloda in iomaíocht le haghaidh cothaitheach leis na miocrorgánaigh ar an líontóir. Mura bhfuil an bithbhreoslaí déanta fós, is féidir an iontógáil uisce a mhéadú chun ligean don sloda scaipeadh sa chóras agus ról ionaclaithe a imirt. Is féidir breithiúnas garbh a dhéanamh ar aibíocht na saothrú sloda ón gcéim bhitheolaíoch. Beidh roinnt protozoa snámha le feiceáil nuair a dhéantar an sloda ar dtús. Má tá líon mór péisteanna agus péisteanna brainseach le feiceáil go mór agus má tá siad gníomhach, is féidir a mheas go ginearálta go n -éiríonn leis an mbithfilm ocsaídiúcháin teagmhála go bunúsach. Mar sin féin, tá eisceachtaí ann. Feidhmíonn roinnt feistí cóireála fuíolluisce de ghnáth, ach is beag nó nach bhfuil aon protozoa seasta ann, mar sin is gá SV agus tosca eile a chur le chéile le haghaidh anailíse. Tar éis foirmiú tosaigh an bhithfhilm, mura bhfuil aon chás speisialta ann, ní gá an sloda san umar dríodair tánaisteach a chur ar ais.
255. C: Tar éis an sloda anaeróbach den ghnáth -imoibreoir oscailte anaeróbach a bheith caillte, conas an toirt fillte a rialú? Conas Stirrer a shuiteáil? Má úsáidtear stirrer báite, cá mhéad limistéar rialaithe atá ag teastáil? A: Baintear amach an láib agus an t -uisce a mheascadh an t -imoibreoir anaeróbach baffled trí shreabhadh an uisce suas agus síos a athrú, agus mar sin níl aon ghá le stirrer a shuiteáil. Tá go leor cúiseanna ann le sloda anaeróbach a chailleadh, nach féidir a nascadh go simplí leis an méid fillte.
256. C: An bhfuil aerú le linn insreabhadh uisce sa lochán ocsaídiúcháin teagmhála nach gcabhródh le foirmiú bithbhreoslaí? An gcuirtear leis an mbreiseán cothaitheach le gach umar bithcheimiceach roimh insreabhadh uisce nó ina dhiaidh? An mbeidh caillteanas cothaitheach mar thoradh ar an mbreiseán le linn insreabhadh uisce? A: Sa phróiseas saothrú bithbhreoslaí, tá caillteanas cothaitheach dosheachanta cibé an aerú nó an t -aerú insreafa uisce é, agus is é an t -aon bhealach ná an caillteanas a íoslaghdú. Ní dóigh liom nach gcabhraíonn aerú le linn insreabhadh uisce le foirmiú bithfhilm. Is í an eochair do shaothrú insreafa uisce leanúnach ná an insreabhadh uisce agus an toirt aeraithe a rialú.
257. C: Tá ár gcuideachta ag caitheamh le fuíolluisce cógaisíochta ina bhfuil cuid mhór substaintí fáinne beinséine. Is é an méid uisce ná 600t/d, agus is é an meán -trosc tionchair ná 27000 mg/L. Próiseas: Pretreatment + Anaeróbach + Linn Sloda Gníomhachtaithe + Dhá linn Ocsaídiúcháin Sraithuimhir. Is é an t -eisilteach reatha ná thart ar 300 mg/L (is é an ceanglas an chéad chaighdeán urscaoilte cuimsitheach - leibhéal, Cod100mg/L nó níos lú). Tá an COD eisiltigh ocsaídiúcháin teagmhála tar éis titim go dtí thart ar 200 mg/L agus ní féidir é a laghdú níos mó. Má leanann sé de bheith aeraithe, méadóidh sé arís. Anois is mian linn aerú ocsaigine íon a úsáid, tástáil phíolótach a dhéanamh ar dtús chun a fháil amach an n -oibríonn sé, agus tá sé i gceist aige carbón gníomhachtaithe a chur leis chun iarracht a dhéanamh. An bhfuil aon bhealaí eile ann? A: Chomh maith le tosca a bhaineann le rialú oibríochta a eisiamh, mura féidir COD a laghdú ach go dtí thart ar 200 mg/L, ciallaíonn sé go bhfuil cóimheas B/C an fhuíolluisce ró -íseal; Má leanann sé ar aghaidh le haeraithe, méadóidh sé arís, ag léiriú go bhfuil an t -am aeraithe ró -fhada agus go bhfuil an bithbhreoslaí ag dul i léig agus go bhfuil sé díscaoilte go páirteach. An é an chúis atá le haerú ocsaigine íon a úsáid toisc nach féidir leis an umar aeraithe go leor ocsaigine a sholáthar? Má tá droch -bhith -dhíghrádú ag an bhfuíolluisce, tá aerú ocsaigine íon gan úsáid. Tá sé úsáideach carbón gníomhachtaithe a chur leis, ach níl sé eacnamaíoch. Braithim go bhfuil fadhbanna ag baint leis an meascán próisis seo, agus níl a fhios agam cén próiseas réamh -chóirithe roimh an bpróiseas anaeróbach, mar sin ní féidir liom trácht a dhéanamh ar a thuilleadh.
258 Ceist: Tar éis PAC agus PAM a chur leis an umar snámhachta, tá srathú soiléir sa seomra imoibriúcháin. Is é an t -ollscoil thart ar 30cm, agus is é an ciseal íochtarach gach dríodar flocculent. Éiríonn an t -eisilteach tuirbiúil tar éis dó dul isteach sa seomra snámhachta. Cad atá ar siúl? Conas é a réiteach? Freagra: Níl a fhios agam an úsáideann tú CAF nó DAF. De réir an méid a dúirt tú, déantar floccules tar éis an gníomhaire a chur leis, ach níl an éifeacht flocasúcháin an -mhaith. Éilíonn sé seo a dheimhniú an bhfuil fadhb sa phróiseas breisithe gníomhaire. Ní féidir PAC agus PAM a chur leis ag an am céanna. Ba chóir go mbeadh aonaid bhreise ar leith ann, agus ba chóir go mbeadh próiseas measctha agus corraitheach cuí ann freisin. Má eisiatar an fachtóir a bhaineann le himoibrithe a chur leis, is é fadhb na n -áiseanna agus an trealaimh snámhachta, mar shampla: neamhleor gáis - comhéadan leachtach; Má tá umar aeir ann, deimhnigh an bhfuil brú an umair aeir gnáth;
259. C: An bhfuil aerú le linn insreabhadh uisce go dtí an lochán ocsaídiúcháin teagmhála díobhálach do fhoirmiú bithfhilm? An gcuirtear leis an mbreiseán cothaitheach le gach umar bithcheimiceach roimh insreabhadh uisce nó ina dhiaidh? An mbeidh caillteanas cothaitheach mar thoradh ar an mbreiseán cothaitheach le linn insreabhadh uisce? A: Sa phróiseas saothrú bithbhreoslaí, ní féidir caillteanas cothaitheach a sheachaint cibé an aerú nó an t -aerú insreabhadh uisce é, agus is é an t -aon bhealach ná an caillteanas a íoslaghdú. Ní dóigh liom go bhfuil aerú le linn insreabhadh uisce díobhálach do fhoirmiú bithbhreoslaí. Is í an eochair do shaothrú insreafa uisce leanúnach ná an insreabhadh uisce agus an toirt aeraithe a rialú.